Typical workflow

This section walks through a typical session: finding the events in a set of automatic picks, locating and checking them, and sending the results back to SeisComP. Each step links to the detailed description.

Load the data

  1. Select the processing profile for the network in the toolbar. It is applied at start-up; press Load next to it if you change it.

  2. Set the time window in the database part of the toolbar, tick picks and, if the existing solutions should be included, origins or pref. origins, and press Load.

    Alternatively open an XML file with File → Open….

  3. If the picks contain duplicates, press Aggregate (Pick aggregation and filtering), or tick aggregate before loading.

Check the picks in the histogram and on the map. Hide noise with the pick filters, for example with Not isolated or the infrasound trace-velocity filter (Pick filters).

Find the events

  1. Choose a nucleation method on the Nucleation tab and press Nucleate (Nucleation). Each detection is added as a preliminary origin.

  2. If the result is poor, tune the parameters with Auto vel., Auto dist. and Auto from a few trusted origins, and nucleate again.

Locate the events

  1. Clear the selection and press Smart-locate all. Every visible origin is associated, relocated and, if successful, accepted (Analyst rules and Smart-locate).

  2. Press Merge origins to combine duplicate detections of the same event (Refining origins).

  3. Repeat Nucleate and Smart-locate all with Show associated unticked in the pick filters: the picks that are now associated are no longer shown and so no longer nucleated, and weaker events can appear. The next section turns this into a fixed sequence over all nucleators.

  4. During swarms, recover further events on the Swarm tab and locate them with Smart-locate all (Swarm tab: recovering further events).

Cascade of nucleators

The nucleators find different events: DBSCAN clusters picks in time and space, back projection and the grid search stack travel times, GaMMA-lite associates phases, EDT location uses the stations that have not picked. Run one after the other, each on the picks the previous ones left over, and keep only what Smart-locate can confirm. Every nucleator then works on a cleaner pick set, and its false seeds are thrown away before the next one starts.

The cascade relies on three rules of catalyst: nucleation and the Swarm tab work on the picks shown, Smart-locate all and Clear origins work on the origins shown, and removing an origin frees its picks again.

Set up the filters once

  1. Load the picks (see above).

  2. In the pick filters untick Show associated. Only the picks that belong to no origin are shown, and only these are nucleated.

  3. In the origin filters untick the status located and press Apply. Origins that Smart-locate has located and accepted disappear from the table; the seeds that are left are shown.

For each nucleator (in the order of the Nucleation tab: DBSCAN, Back projection, GaMMA-lite, Grid search, EDT location)

  1. Open its page and press Nucleate. The seeds are added as preliminary origins and appear in the origin table.

  2. Clear the selection and press Smart-locate to locate all shown origins. The seeds that can be located are accepted and vanish from the table, because located origins are hidden. Their picks are now associated and vanish from the pick table, too.

  3. The origins still shown are the seeds Smart-locate could not locate. Press Clear origins (QC tab): it removes only the origins shown, so the located ones are kept. The picks of the removed seeds are free again and shown in the pick table for the next nucleator.

After the last nucleator

  1. Reset the origin filters (Reset all). All origins are shown again.

  2. Press Merge origins on the Aggregation tab. Different nucleators often found the same event; merging combines these duplicates (Refining origins).

  3. Press Calculate spectra on the QC tab. It computes Arch [dB], Arch n and Post [dB] for the origins shown with the profile’s spectra settings (Spectra).

  4. Apply the spectra rule sets on the QC tab (Quality control). The spectra tell whether an origin is a real event: a real event lifts P and S above the noise at several stations. The confirm rule adds the azimuthal gap, so a confirmed origin is both a real event and well located: stations on all sides constrain the epicentre. For example:

    Spectra - confirmed:  Arch [dB] >= 2 AND Arch n >= 2
                          AND Azimuthal gap <= 270
    

    Select the rule set, check the matches with Select matching or Star matching, then press Confirm matching. The origins that are not confirmed are left for review: either no clear event in the spectra, or a location with a large gap.

    The thresholds depend on the network and on the spectra settings of the profile; set them once on reviewed origins and keep them in the rule set.

Note

Tick Show associated again before you look at single origins: with it unticked, the arrivals of the origins are missing from the pick table.

Review single origins

Select an origin to inspect it in the ACTIVE ORIGIN panel. The Travel-time plot shows at a glance whether the picks follow the curves (Analyst rules and Smart-locate). To improve an origin by hand:

  • box-select unassociated picks on the plot to associate them,

  • click arrivals to stop using them,

  • press Relocate and, if the candidate is better, Accept origin,

  • or press Smart-locate and review the candidate.

Reset returns to the first stored solution. Review in scolv opens the origin in scolv for a full review with waveforms.

Check the quality

  1. Select a QC rule set on the QC tab, or build the conditions (Quality control).

  2. Press Select matching or Star matching to review the matching origins.

  3. Press Confirm matching, Reject matching or Remove matching to apply the decision.

Use the origin filter to apply a rule set to a part of the catalogue only.

Send or save the results

File → Send Selection to Messaging sends the origins that were merged, relocated or accepted since loading or since the last send. Only these updated origins are sent; origins that did not change are skipped.

  • The origins are sent as new objects. The picks they refer to already exist in SeisComP and are not sent again.

  • Arrivals that refer to virtual picks are removed before sending, because virtual picks exist only in catalyst.

  • The confirmation dialog shows the number of origins and the messaging group. Sending cannot be undone from catalyst.

catalyst must be started with a messaging connection (-H) to send.

To keep the results as a file instead, use File → Save As… or Save Selection As….

Save the settings that worked with Save as… next to the profile selector, so the next session starts from them (Processing profiles).