access

Access module for FDSNWS.

Bindings Parameters

Note

access.* Defines access to restricted data. When defined it will add the listed users to the list of authorized users to access certain restricted data give the parameters on this binding.

access.users

Type: list:string

List of users (e-mail addresses) allowed to access the restricted data.

access.disableStationCode

Default: false

Type: boolean

When disableStationCode option is set to true the access entries will be generated only for the network level (and optionally stream level), no station code will be filled (this can potentially reduce the number of entries on the access table, and save memory on the request handler when used).

access.streams

Type: list:string

List of locations.streams this access rule applies to. The location code is optional (optional, allow wildcards).

access.start

Type: datetime

Start of validity (optional).

access.end

Type: datetime

End of validity (optional).